24’x36′ Portable Classroom Floor Plan: 20 Students in 864 Sq Ft

iModular.com
Commercial modular buildings · Brokered nationwide since 1998
Call Matt Banes: (800) 806-7485
www.imodular.com/modular-building-floor-plans/24×36-portable-classroom/
Plan PC-2436
24’x36′ Portable Classroom Floor Plan: 20 Students in 864 Sq Ft

This 24’x36′ portable classroom gives you one open 864 sq ft room for 20 students, with an ADA ramp and two exits. It fits smaller sites than the standard 24’x40′.

The 24’x36′ portable classroom floor plan

View full size  |  Print floor plan  |  Share this plan  |  Request a price for this plan

First, tap this 24’x36′ portable classroom floor plan to zoom in. Then use the links under the plan to print it or share it with your team.

24’x36′ portable classroom specs at a glance

Here are the key specs for this 24’x36′ portable classroom floor plan, so you can compare it with your site and your needs.

Box size24’x36′
Floor area864 sq ft
Sections2 (two 12’x36′ modules)
ClassroomOne open 24’x36′ room for 20 students
RestroomsNone inside; use campus restrooms or a restroom building
Best forSmall classes, special education, tutoring and tight sites
Exits and accessMain entry with a 5’x5′ landing and an ADA ramp, plus a second exit with a landing and steps
HVAC2 wall-mount units on the east end wall (1 per module)
Plan IDPC-2436

Room schedule

RoomSizeSq ft
Classroom (20 students)24’x36′864

We measure the rooms to the module lines, so interior walls take a few inches from each room.

How this layout works

  • Students enter at the west end, up the ADA ramp
  • The room is one open space with desks facing the teaching wall
  • A second exit on the north wall gives two ways out
  • HVAC units on the east wall keep the long walls free for windows

Exits, ramps and life safety

We draw every iModular.com plan with life safety and ADA access in mind. Exits are marked in red on the drawing. Here is how this layout handles them:

  • Two exits: the main entry and a second exit on the north wall
  • The main entry has a 5’x5′ landing and an ADA ramp, and the second exit has a landing with steps
  • Both exterior doors swing out, in the direction of travel

Your local building department and fire marshal have the final say on exits, alarms and sprinklers, so share this plan with them early.

Like every iModular.com plan, this one follows a few more rules: wall-mount HVAC units sit on the end wall, and that wall has no windows; restrooms and sinks are on exterior walls, which keeps plumbing runs short; and restrooms have no windows. Also, every layout can change. For example, we can move walls, doors and windows before the factory builds a new building, and a contractor can often remodel a used one after delivery.

Who uses a modular portable classroom

Buyers often choose this layout for uses like these. However, the same layout works for many other jobs, too.

  • Schools with small classes or special education programs
  • Private schools on tight lots
  • Tutoring and learning centers
  • Churches running Sunday school or a preschool
  • Training rooms for businesses

Planning a 24’x36′ portable classroom

A 24’x36′ fits where a 24’x40′ won’t, and it still holds a full small class. If you need restrooms in the room, step up to the 24’x40′ portable classroom with restrooms.

Delivery and site setup

A 24’x36′ portable classroom ships as two 12’x36′ modules, each on its own chassis, so it takes two trucks. Each 12′-wide module moves as an oversize load with a permit. On site, the crew joins the modules at the marriage line, then the building needs a level pad, the ramp and landings, and power, water, sewer and data hookups (by others).

As a result, the site work usually comes down to a level pad, a foundation, utility hookups and access. Also, ask your city or county early, because local permits often set the schedule.

Approvals where you are

In short, the building is the same everywhere. Instead, what changes is the state program that approves it and how your city or county permits the site work. For example, in California the Department of Housing and Community Development (HCD) approves commercial modular buildings (California prices and guides). In Texas, the TDLR Industrialized Housing and Buildings program covers them (Texas guide). Similarly, Florida uses the DBPR manufactured buildings program (Florida guide). Either way, iModular.com brokers modular buildings nationwide. Read how permits work for modular buildings.

Compare nearby sizes and layouts

Also, if this layout is close but not quite right, compare these:

Buy or rent a 24’x36′ portable classroom

iModular.com sells new and used modular buildings and arranges rentals and leases. In many cases, a used building is the fastest and lowest-cost way to get this size, or one close to it. Learn how to buy a used modular building, or compare financing, leasing and rental.

Get pricing on a 24’x36′ portable classroom

New or used, buy or rent. Mention plan PC-2436 and we will price this layout or one close to it.

Call (800) 806-7485  ·  Matt answers six days a week  ·  Request a price online

Request a price for this plan

Where will the building go?

Frequently asked questions

How big is a 24’x36′ portable classroom?

A 24’x36′ portable classroom has 864 sq ft of floor area. This plan ships as two 12’x36′ modules, each on its own chassis, so it takes two trucks. Each 12′-wide module moves as an oversize load with a permit.

How many students fit in a 24’x36′ portable classroom?

About 20 students at desks. Your state and building department set the final number.

Is 24’x36′ a common used classroom size?

It is less common than 24’x40′, so stock is thinner. We can often find a 24’x40′ that fits nearly the same space.

Can I buy a used 24’x36′ portable classroom?

Often, yes. iModular.com sells new and used modular buildings nationwide, and a used building close to this size is usually the fastest and lowest-cost option. Call (800) 806-7485 and mention plan PC-2436.

Can you change this portable classroom floor plan?

Yes. We can move walls, doors and windows before the factory builds a new building, and a contractor can often remodel a used one after delivery. Your building department has the final say on exits, restrooms and accessibility.

Questions about this plan? Call Matt Banes at (800) 806-7485
Matt answers six days a week and can price this layout new or used, to buy or rent. Mention plan PC-2436.
iModular.com · www.imodular.com/modular-building-floor-plans/24×36-portable-classroom/

Drawn by iModular.com. Schematic concept, not for construction and not to scale. Final drawings by a licensed professional. © 2026 iModular.com. Reviewed by Matt Banes · Plan PC-2436 · Updated November 20, 2026.