This 24’x32′ portable classroom is the smallest double-wide classroom in our library: one open 768 sq ft room for 16 students, with an ADA ramp and two exits.
The 24’x32′ portable classroom floor plan

View full size | Print floor plan | Share this plan | Request a price for this plan
First, tap this 24’x32′ portable classroom floor plan to zoom in. Then use the links under the plan to print it or share it with your team.
24’x32′ portable classroom specs at a glance
Here are the key specs for this 24’x32′ portable classroom floor plan, so you can compare it with your site and your needs.
| Box size | 24’x32′ |
| Floor area | 768 sq ft |
| Sections | 2 (two 12’x32′ modules) |
| Classroom | One open 24’x32′ room for 16 students |
| Restrooms | None inside |
| Best for | Small groups, intervention rooms, music or art, and offices |
| Exits and access | Main entry with a 5’x5′ landing and an ADA ramp, plus a second exit with a landing and steps |
| HVAC | 2 wall-mount units on the east end wall (1 per module) |
| Plan ID | PC-2432 |
Room schedule
| Room | Size | Sq ft |
|---|---|---|
| Classroom (16 students) | 24’x32′ | 768 |
We measure the rooms to the module lines, so interior walls take a few inches from each room.
How this layout works
- Students enter at the west end, up the ADA ramp
- The room is one open space
- A second exit on the north wall gives two ways out
- The size also works as a small office or meeting room
Exits, ramps and life safety
We draw every iModular.com plan with life safety and ADA access in mind. Exits are marked in red on the drawing. Here is how this layout handles them:
- Two exits: the main entry and a second exit on the north wall
- The main entry has a 5’x5′ landing and an ADA ramp, and the second exit has a landing with steps
- Both exterior doors swing out, in the direction of travel
Your local building department and fire marshal have the final say on exits, alarms and sprinklers, so share this plan with them early.
Like every iModular.com plan, this one follows a few more rules: wall-mount HVAC units sit on the end wall, and that wall has no windows; restrooms and sinks are on exterior walls, which keeps plumbing runs short; and restrooms have no windows. Also, every layout can change. For example, we can move walls, doors and windows before the factory builds a new building, and a contractor can often remodel a used one after delivery.
Who uses a modular portable classroom
Buyers often choose this layout for uses like these. However, the same layout works for many other jobs, too.
- Schools needing a small-group or intervention room
- Preschools and daycare rooms
- Art, music and counseling rooms
- Churches and nonprofits
- Small offices and meeting rooms
Planning a 24’x32′ portable classroom
A 24’x32′ is a good fit for a small class or a support room. For a full class of 24, look at the 24’x40′ portable classroom.
Delivery and site setup
A 24’x32′ portable classroom ships as two 12’x32′ modules, each on its own chassis, so it takes two trucks. Each 12′-wide module moves as an oversize load with a permit. On site, the crew joins the modules at the marriage line, then the building needs a level pad, the ramp and landings, and power, water, sewer and data hookups (by others).
As a result, the site work usually comes down to a level pad, a foundation, utility hookups and access. Also, ask your city or county early, because local permits often set the schedule.
Approvals where you are
In short, the building is the same everywhere. Instead, what changes is the state program that approves it and how your city or county permits the site work. For example, in California the Department of Housing and Community Development (HCD) approves commercial modular buildings (California prices and guides). In Texas, the TDLR Industrialized Housing and Buildings program covers them (Texas guide). Similarly, Florida uses the DBPR manufactured buildings program (Florida guide). Either way, iModular.com brokers modular buildings nationwide. Read how permits work for modular buildings.
Compare nearby sizes and layouts
Also, if this layout is close but not quite right, compare these:
- 24’x36′ portable classroom floor plan – 864 sq ft
- 24’x40′ portable classroom floor plan – 960 sq ft
- 24’x36′ modular building floor plan – 864 sq ft
- 24’x40′ modular building floor plan – 960 sq ft
- Browse every size in our modular building floor plans library
Buy or rent a 24’x32′ portable classroom
iModular.com sells new and used modular buildings and arranges rentals and leases. In many cases, a used building is the fastest and lowest-cost way to get this size, or one close to it. Learn how to buy a used modular building, or compare financing, leasing and rental.
Get pricing on a 24’x32′ portable classroom
New or used, buy or rent. Mention plan PC-2432 and we will price this layout or one close to it.
Call (800) 806-7485 · Matt answers six days a week · Request a price online
Request a price for this plan
Where will the building go?
Frequently asked questions
How big is a 24’x32′ portable classroom?
A 24’x32′ portable classroom has 768 sq ft of floor area. This plan ships as two 12’x32′ modules, each on its own chassis, so it takes two trucks. Each 12′-wide module moves as an oversize load with a permit.
How many students fit in a 24’x32′ portable classroom?
About 16 students at desks. Your state and building department set the final number.
Can a 24’x32′ be used as an office?
Yes. It works well as an open office, a meeting room or two private offices.
Can I buy a used 24’x32′ portable classroom?
Often, yes. iModular.com sells new and used modular buildings nationwide, and a used building close to this size is usually the fastest and lowest-cost option. Call (800) 806-7485 and mention plan PC-2432.
Can you change this portable classroom floor plan?
Yes. We can move walls, doors and windows before the factory builds a new building, and a contractor can often remodel a used one after delivery. Your building department has the final say on exits, restrooms and accessibility.
Drawn by iModular.com. Schematic concept, not for construction and not to scale. Final drawings by a licensed professional. © 2026 iModular.com. Reviewed by Matt Banes · Plan PC-2432 · Updated November 20, 2026.